Модульное общежитие на 150 мест
<style>
table {
border-collapse: collapse;
width: 100%;
max-width: 100%;
background-color: #fff;
box-shadow: 0 2px 5px rgba(0,0,0,0.1);
}
caption {
caption-side: top;
font-weight: bold;
font-size: 20px;
margin-bottom: 10px;
}
th, td {
border: 1px solid #ccc;
padding: 10px 15px;
text-align: left;
vertical-align: top;
word-break: break-word;
}
th {
background-color: #e6e6e6;
}
/* Адаптивность */
@media screen and (max-width: 768px) {
table, thead, tbody, th, td, tr {
display: block;
width: 100%;
}
thead tr {
display: none;
}
tr {
margin-bottom: 15px;
border: 1px solid #ddd;
padding: 10px;
}
td {
border: none;
padding: 8px 0;
position: relative;
padding-left: 50%;
}
td:before {
position: absolute;
left: 15px;
width: 45%;
padding-right: 10px;
white-space: nowrap;
font-weight: bold;
}
td:nth-of-type(1):before { content: "Параметр"; }
td:nth-of-type(2):before { content: "Значение"; }
td:nth-of-type(3):before { content: "Примечание"; }
}
</style>
<table>
<caption>Технические характеристики</caption>
<thead>
<tr>
<th>Параметр</th>
<th>Значение</th>
<th>Примечание</th>
</tr>
</thead>
<tbody>
<tr>
<td>Диапазон рабочих температур, °С</td>
<td>-50...+50</td>
<td></td>
</tr>
<tr>
<td>Климатические нагрузки, кг/м2</td>
<td>Устанавливаются актуальной редакцией СП 20.13330</td>
<td>Снеговая, ветровая нагрузки</td>
</tr>
<tr>
<td>Равномерно-распределённая нагрузка, кг/м2</td>
<td>200, 300 *</td>
<td>Полезная нагрузка на стандартную раму модуля в основных помещениях, кроме мест скопления людей. * В коридорах зданий</td>
</tr>
<tr>
<td>Срок службы, лет</td>
<td>От 10 лет и свыше 50 лет</td>
<td>В зависимости от выполнения условий эксплуатации и проектных решений</td>
</tr>
<tr>
<td>Толщина изоляции перекрытий, мм</td>
<td>150, 200, 250</td>
<td>Теплоизоляция внешнего контура не ограничивается 250 мм и может быть увеличена до необходимого проектного решения в комплексе за счет конструкции серийной кровли и комплекта теплоизоляции ростверка.</td>
</tr>
<tr>
<td>Тип теплоизоляции перекрытий</td>
<td>Плита минераловатная DOORHAN «ЛАЙТ» 35–1 200 × 600 × 50/8</td>
<td></td>
</tr>
<tr>
<td>Толщина изоляции стеновых панелей, мм</td>
<td>50, 60, 80 *, 100 *, 120, 150 *, 180, 200 *, 250 *</td>
<td>В панелях применяется теплоизоляция на основе минеральной плиты и пенополиизоцианурата, * Основные серийные толщины минераловатной изоляции</td>
</tr>
<tr>
<td>Степень огнестойкости здания</td>
<td>II степень</td>
<td>Достигается за счет комплексных решений DoorHan при строительстве по рекомендованным решениям</td>
</tr>
<tr>
<td>Класс конструктивной пожарной опасности</td>
<td>С0</td>
<td>Достигается с помощью решений, регламентированных протоколами испытаний и сертификатами и другой нормативной документацией, при проектировании.</td>
</tr>
</tbody>
</table>
table {
border-collapse: collapse;
width: 100%;
max-width: 100%;
background-color: #fff;
box-shadow: 0 2px 5px rgba(0,0,0,0.1);
}
caption {
caption-side: top;
font-weight: bold;
font-size: 20px;
margin-bottom: 10px;
}
th, td {
border: 1px solid #ccc;
padding: 10px 15px;
text-align: left;
vertical-align: top;
word-break: break-word;
}
th {
background-color: #e6e6e6;
}
/* Адаптивность */
@media screen and (max-width: 768px) {
table, thead, tbody, th, td, tr {
display: block;
width: 100%;
}
thead tr {
display: none;
}
tr {
margin-bottom: 15px;
border: 1px solid #ddd;
padding: 10px;
}
td {
border: none;
padding: 8px 0;
position: relative;
padding-left: 50%;
}
td:before {
position: absolute;
left: 15px;
width: 45%;
padding-right: 10px;
white-space: nowrap;
font-weight: bold;
}
td:nth-of-type(1):before { content: "Параметр"; }
td:nth-of-type(2):before { content: "Значение"; }
td:nth-of-type(3):before { content: "Примечание"; }
}
</style>
<table>
<caption>Технические характеристики</caption>
<thead>
<tr>
<th>Параметр</th>
<th>Значение</th>
<th>Примечание</th>
</tr>
</thead>
<tbody>
<tr>
<td>Диапазон рабочих температур, °С</td>
<td>-50...+50</td>
<td></td>
</tr>
<tr>
<td>Климатические нагрузки, кг/м2</td>
<td>Устанавливаются актуальной редакцией СП 20.13330</td>
<td>Снеговая, ветровая нагрузки</td>
</tr>
<tr>
<td>Равномерно-распределённая нагрузка, кг/м2</td>
<td>200, 300 *</td>
<td>Полезная нагрузка на стандартную раму модуля в основных помещениях, кроме мест скопления людей. * В коридорах зданий</td>
</tr>
<tr>
<td>Срок службы, лет</td>
<td>От 10 лет и свыше 50 лет</td>
<td>В зависимости от выполнения условий эксплуатации и проектных решений</td>
</tr>
<tr>
<td>Толщина изоляции перекрытий, мм</td>
<td>150, 200, 250</td>
<td>Теплоизоляция внешнего контура не ограничивается 250 мм и может быть увеличена до необходимого проектного решения в комплексе за счет конструкции серийной кровли и комплекта теплоизоляции ростверка.</td>
</tr>
<tr>
<td>Тип теплоизоляции перекрытий</td>
<td>Плита минераловатная DOORHAN «ЛАЙТ» 35–1 200 × 600 × 50/8</td>
<td></td>
</tr>
<tr>
<td>Толщина изоляции стеновых панелей, мм</td>
<td>50, 60, 80 *, 100 *, 120, 150 *, 180, 200 *, 250 *</td>
<td>В панелях применяется теплоизоляция на основе минеральной плиты и пенополиизоцианурата, * Основные серийные толщины минераловатной изоляции</td>
</tr>
<tr>
<td>Степень огнестойкости здания</td>
<td>II степень</td>
<td>Достигается за счет комплексных решений DoorHan при строительстве по рекомендованным решениям</td>
</tr>
<tr>
<td>Класс конструктивной пожарной опасности</td>
<td>С0</td>
<td>Достигается с помощью решений, регламентированных протоколами испытаний и сертификатами и другой нормативной документацией, при проектировании.</td>
</tr>
</tbody>
</table>